Sign In | Join Free | My himfr.com
Home > Edible Oil Testing Equipment >

Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell

    Buy cheap Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell from wholesalers
     
    Buy cheap Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell from wholesalers
    • Buy cheap Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell from wholesalers
    • Buy cheap Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell from wholesalers

    Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell

    Ask Lasest Price
    Brand Name : Shandong Shengtai Instrument
    Model Number : ST-64B
    Certification : GB/T7702.14-2008
    Payment Terms : T/T
    Supply Ability : 10000 sets/year
    Delivery Time : 7-15 work days
    • Product Details
    • Company Profile

    Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell

    ST-64B Activated carbon penetration sulfur capacity tester


    ST-64B activated carbon penetration capacity testing device is developed in accordance with the national standard GB/T7702.14-2008 "Test methods for coal based granular activated carbon - Determination of sulfur capacity". It is suitable for testing the penetration capacity of coal based granular activated carbon, as well as for testing the penetration capacity of other types of activated carbon.

    Experimental principle:

    The test sample is burned in a purified air flow at a high temperature of 1050 ℃, and various forms of sulfur in the coal are decomposed and carried to the electrolysis cell by the air flow to combine with water to generate H2SO3. Due to its disruption of the dynamic equilibrium of the original iodine iodine ion pairs in the electrolysis cell, the instrument immediately outputs a current to electrolyze potassium iodide solution to generate iodine, in order to restore the original dynamic equilibrium, which is the Coulomb titration in GB/T214-1996. The amount of current consumed to restore the original dynamic equilibrium is related to the sulfur decomposed during combustion in the laboratory sample, which can be measured and calculated by a microprocessor

    Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell

    Technical parameters

    Measurement range of total sulfur:0-10%

    The sample combustion analysis time is 3-8 minutes, and the titration endpoint is automatically determined and returned.

    Temperature control:500-1150 degrees Celsius, controllable ± 3 ℃. Temperature measurement: accuracy level 0.5; The heating element is a silicon carbon tube, with a high-temperature zone length of ≥ 90 millimeters. The experimental temperature is 1050 ℃± 5 ℃ (the temperature can be adjusted as needed).

    Heating rate:25-30 ℃/min, up to 1050 ℃ in about 30 minutes.

    Electrolytic cell:with a volume of 450 milliliters and a platinum metal electrode.

    The stability of the instrument:It enters a stable state within 1 minute of starting up.

    Rated power supply:220V±10% 50HZ

    Measurement range 0-10% Activated carbon penetration sulfur capacity tester 450ml electrolytic cell

    Measurement range of total sulfur0-10%
    Combustion analysis time3-8 minutes
    Temperature control500-1150℃
    Controllable±3℃
    Temperature measurement: accuracylevel 0.5
    Heating elementSilicon carbon tube
    Length of high temperature zone≥90 millimeters
    Experimental temperature1050℃±5℃(temperature can be adjusted as needed)
    Heating speed25-30℃/min,About 30 minutes to reach 1050 ℃
    Electrolytic cellwith a volume of 450 milliliters and a platinum metal electrode.
    The stability of the instrumentIt enters a stable state within 1 minute of starting up.
    Rated power supply220V±10% 50HZ

    ST-64B activated carbon penetration capacity testing device is developed in accordance with the national standard GB/T7702.14-2008 "Test methods for coal based granular activated carbon - Determination of sulfur capacity". It is suitable for testing the penetration capacity of coal based granular activated carbon, as well as for testing the penetration capacity of other types of activated carbon.

    Experimental principle:

    The test sample is burned in a purified air flow at a high temperature of 1050 ℃, and various forms of sulfur in the coal are decomposed and carried to the electrolysis cell by the air flow to combine with water to generate H2SO3. Due to its disruption of the dynamic equilibrium of the original iodine iodine ion pairs in the electrolysis cell, the instrument immediately outputs a current to electrolyze potassium iodide solution to generate iodine, in order to restore the original dynamic equilibrium, which is the Coulomb titration in GB/T214-1996. The amount of current consumed to restore the original dynamic equilibrium is related to the sulfur decomposed during combustion in the laboratory sample, which can be measured and calculated by a microprocessor